Leave Your Message
WST de-energized, combined, linear tap changer. Star-delta ZH2 Opening dimensions Φ43

De-energized linear tap changer

WST de-energized, combined, linear tap changer. Star-delta ZH2 Opening dimensions Φ43

The tap changer is specifically designed for triple-phase oil-insulated transformers operating at frequencies of 50Hz and 60Hz. It is suitable for transformers with a maximum equipment voltage of 10kV and 24kV, and a rated through-current of 30A and 63A. The tap changer can be conveniently fixed on the transformer tank cover and replaced when the transformer is not energized.

    Model Meaning

    rfvk82

    Advantages

    1. The tap changer is designed with a reasonable structure, ensuring a small size and low requirements for installation space.
    2. The tap changer features a gear shifting design that offers flexibility, precise positioning, and the ability to effortlessly meet diverse needs, resulting in efficient control.
    3. The tap changer is equipped with a low contact resistance, which ensures the circuit operates with stability and efficiency.
    4. The tap changer is manufactured following standardized production processes and can be customized according to individual requirements. It offers cost savings while ensuring the same level of quality.

    Details

    Phase Triple
    Rated voltage 10kV,35kV
    Rated current 63A~250A
    Voltage regulation 0.025
    Tapping positions 3~5

    Voltage Regulation Principle

    wdcslc

    Outline

    trf8mw

    No. Install dimension  mm
    Model  No. Regulating position L L1 L2 L4 L5 L6 H H1 H2
    1 WSTⅣ63/10-4×3ZH2 Y-△ Central 478 188 145 99 24 34 180 78 70
    2 WSTⅣ125/10-4×3ZH2 705 265 220 107 29 70 180 78 70
    3 WSTⅣ250/10-4×3ZH2 705 265 220 112 29 70 180 78 70
    4 WSTⅣ63/35-4×3ZH2 705 265 220 103 29 70 210 98 80
    5 WSTⅣ125/35-4×3ZH2 705 265 220 107 34 70 210 98 80
    6 WSTⅣ250/35-4×3ZH2 705 265 220 112 34 70 210 98 80
    7 WSTⅣ63/10-6×5ZH2 622 236 193 99 24 34 180 78 70
    8 WSTⅣ125/10-6×5ZH2 705 265 220 107 29 70 180 78 70
    9 WSTⅣ250/10-6×5ZH2 705 265 220 112 29 70 180 78 70
    10 WSTⅣ63/35-6×5ZH2 755 285 235 103 29 70 210 98 80
    11 WSTⅣ125/35-6×5ZH2 755 285 235 107 34 70 210 98 80
    12 WSTⅣ250/35-6×5ZH2 755 285 235 112 34 70 210 98 80

    Voltage Regulating Schematic

    ujkiv6n

    Outline Drawing

    tgfvgzg

    No. Model  No. Regulating position Install dimension  mm
    L L1 L2 L4 L5 L6 L7 H H1 H2 H3 ΦC
    1 WSTⅣ63/10-4×2ZH2 Y-△ Central 576 222 177 99 34 24 ----- 180 78 70 67 80
    WSTⅡ63/10-4×3
    2 WSTⅣ63/10-4×2ZH2 622 236 193 -----
    WSTⅡ63/10-6×5
    3 WSTⅣ125/10-4×2ZH2 688 256 216 107 29 ----- 185
    WSTⅡ125/10-4×3
    4 WSTⅣ125/10-4×2ZH2 912 334 289 107/118 70 11
    WSTⅡ125/10-6×5
    5 WSTⅣ250/10-4×2ZH2 112/123 11
    WSTⅡ250/10-4×3
    6 WSTⅣ250/10-4×2ZH2 11
    WSTⅡ250/10-6×5
    7 WSTⅣ300/10-4×2ZH2 1064 410 327 34 11 75 105
    WSTⅡ300/10-6×5

    Read more